Data transmission and instrumentation

ULX FRXOHR16 Cca
Marcatura 
<meters> CE 0987 SPECIALCAVI BALDASSARI ULX FRXOHR <formation> 450/750V IEC 60332-3-24 <lot> <year> DCA-S3,D0,A3
Manufacturing characteristics
Core 

Flexible tinned copper

Insulation 

PVC compound, R2 type

Stranding 

Cores twisted in pairs

Pairs stranded in concentric layers

Wrapping and protection 

Overall polyester tape

Screen 

Overall aluminium/polyester tape with flexible tinned copper drain-wire

Outer sheath 

PVC compound, R16 type

Colours 

Colori anime:
DIN 47100
Colore guaina esterna:
Grigio (basato su RAL 7035)

Electrical characteristics
Tensione di esercizio anime 

300/300V

Tensione di esercizio guaina esterna 
450/750V
Tensione di prova 

1500V

Certifications
Standard 

CEI 20-29 IEC 60228
CEI 20-11 
CEI EN 60332-3-24 Cat.C IEC 60332-3-24 Cat.C
CEI UNEL 36762

Reaction to Fire Class 
EN 50575:2016 Cca - s2, d0, a3
Temperature
Temperatura minima di esercizio 

-15°C

Temperatura massima di esercizio 

+70°C

Temperatura massima cortocircuito 
+160°C
On request 

• Armatura a treccia di acciaio zincato con guaina esterna con tensione isolamento 450/750V
• Guaina esterna con tensione 0.6/1kV per posa in esterno o in cavidotto interrato
• Colori anime/guaina personalizzati

Laying conditions
Minimum installation temperature 0°
Laying operation bending radius d10
Max tensile stress: 50N/mm^2 of the copper cross-section
Fixed Laying
In open air
In duct or cable tray
Applications 

Cable conforms to the requirements in the Construction Products Regulations (CPR EU 305/11), aimed at limiting the production and diffusion of fire and smoke.

Overall shielded multipair cable suitable for electronic, data transmission between central and peripheral units through ports (RS232) and for interconnections between devices where a high quality of the transmitted signals is required.

This cable can always be installed in coexistence with 450/750V power cables. Furthermore, if it’s used to supply power 

to category 0 systems (nominal voltage less than or equal to 50V AC, or 120V non-inverted DC), it can also be installed in coexistence with 0.6/1kV power cables that supply 230/400V nominal voltage loads.

Underground laying is not permitted, even if protected.