Power, control and signalling - Low smoke zero halogen

XSLCH-J MOTOR 4G ULTRA B2ca
Marcatura 
<meters> CE 0987 SPECIALCAVI BALDASSARI XSLCH-J <formation> IEC 60332-3-24 <lot> <year> B2CA-S1A,D0,A1
Manufacturing characteristics
Core 

Flexible bare copper conductor, class 5

Insulation 

Cross-linked LSZH compound

Stranding 

Cores stranded in concentric layers

Wrapping and protection 

Overall polyester tape

Screen 

1st screen:
Overall aluminium/polyester tape
2nd screen:
Overall tinned copper braid

Outer sheath 

LSZH thermoplastic compound

Colours 

Cores identification:
Brown + Black + Grey + Green/Yellow
Outer sheath colour:
Black (based on RAL 9005)

Electrical characteristics
Tensione di esercizio anime 

0.6/1kV

Tensione di esercizio guaina esterna 
1.8kV D.C. and 1.2kV A.C.
Tensione di prova 

4000V

Certifications
Standard 

IEC 60228
IEC 60332-3-24 Cat.C

Reaction to Fire Class 
EN 50575:2016 B2ca - s1a, d0, a1
Temperature
Temperatura minima di esercizio 
  • Fixed laying: -40°C
  • Occasional mobile laying w/o stress: -5°C
Temperatura massima di esercizio 
  • Fixed laying: +90°C
  • Occasional mobile laying w/o stress: +90°C
Temperatura massima cortocircuito 
+250°C
On request 
  • Customized cores identification/outer sheath colour
Laying conditions
Minimum installation temperature -10°C
Laying operation bending radius: see technical data sheet
Max tensile stress: see tecnica data sheet
Fixed Laying
Posa mobile occasionale aciclica senza stress
In open air
In duct or cable tray
In buried trough
Buried with protection
In buried duct
Directly buried
The cable stored outside must be protected from UV rays
Applications 

Cable conforms to the requirements in the Construction Products Regulations (CPR EU 305/11), aimed at limiting the production and diffusion of fire and smoke.
Shielded LSZH cable used to power motors with frequency converters when full electromagnetic compatibility (EMC) is required. The cable, made entirely of halogen-free materials, does not emit harmful substances in the event of a fire. Suitable for both static and dynamic connections (occasional movement) in industrial plants, process lines and machines operating in dry or damp environments.
If stored/placed outdoors, the cable must be protected from UV rays.
Direct or indirect underground laying is permitted (presence of water condiction AD7). 